Zetasizer for vaccine development

Gain reproducible insight into particle and molecular behaviour in vaccine systems. Detect instability, optimise formulations and accelerate vaccine development with Zetasizer.

Vaccine Development

Vaccines rely on complex biological systems where particle size, molecular stability and formulation behaviour directly influence safety, efficacy and manufacturability. From protein subunit vaccines to viral vectors and nanoparticle delivery systems, developers must carefully characterise biological particles to ensure consistent immune response and long-term stability. 

However, small changes in particle size, aggregation or molecular interactions can significantly impact vaccine performance. These changes often begin at the nanoscale, long before they can be detected using conventional analytical techniques.

To move forward with confidence, scientists need analytical tools that provide clear, reproducible insight into particle behaviour in solution.

That is why vaccine researchers worldwide rely on Zetasizer, delivering particle and molecular characterisation data they can trust at every stage of development.

 

Om_logo.png  Works with OmniTrust: Malvern Panalytical's compliance solution for the regulated environment

 

Would you like to speak to a specialist?
 

When you submit this form, we'll use your data to respond to your inquiry. You will also be opting in to our marketing. We’ll use your data to send you relevant updates on products services, promotions, education material and events related to your country, technology of interest and operating industry. You can unsubscribe at any time. For more information please read our Privacy Policy. 

The hidden risks in vaccine development and how Zetasizer solves them

Even well-designed vaccine candidates can face failure in later stages of development due to:

  • Undetected particle aggregation
  • Formulation instability
  • Variability in nanoparticle or viral vector behaviour
  • Loss of antigen integrity or immunogenic activity

These risks are particularly challenging because they often originate at the nanoscale, long before visible changes occur or traditional techniques can detect them.

Why vaccine development fails late

Subtle changes in particle size, surface charge and molecular interactions can have a profound impact on vaccine stability, efficacy and manufacturability. These early instabilities are often missed during initial screening and only become apparent under real-world conditions such as scale-up, storage or distribution.

Zetasizer is designed to uncover these hidden risks earlier in development.

Using highly sensitive dynamic light scattering (DLS) and zeta potential analysis, Zetasizer detects even the smallest changes in particle size and surface charge.

This enables scientists to identify early-stage instability, aggregation and interaction changes before they become critical issues. The result is faster, more informed decision-making and reduced risk of late-stage failure.

Detect vaccine particle instability before it impacts performance

Particle instability is one of the leading causes of reduced vaccine efficacy. Aggregation, particle growth or structural changes can compromise antigen performance and consistency.

The challenge is that these instabilities often begin at the nanoscale, making them difficult to detect using traditional methods. Zetasizer reveals these early changes with exceptional sensitivity.

By measuring subtle shifts in particle size distribution using dynamic light scattering, Zetasizer enables researchers to monitor vaccine stability directly in solution throughout development.

With Zetasizer, vaccine researchers can:

✔ Detect early particle aggregation before visible instability occurs
✔ Monitor nanoparticle, antigen or viral vector size during development
✔ Compare vaccine candidates with greater analytical confidence

The result is earlier identification of stability risks and more robust vaccine design.

Optimizing vaccine formulations with reliable analytical insight

Vaccines must remain stable across manufacturing, storage, distribution and administration. Even minor changes in pH, buffer composition or excipient interactions can significantly affect particle behaviour and antigen stability.

Zetasizer provides powerful insight into formulation stability.

By measuring both particle size and zeta potential, Zetasizer helps scientists understand how vaccine components interact in solution and predict whether systems will remain stable or begin to aggregate.

This enables rapid screening of formulation conditions and identification of those that support long-term stability.

With Zetasizer, scientists can:

✔ Evaluate particle stability across multiple formulation conditions
✔ Predict colloidal stability using surface charge measurements
✔ Identify buffer systems that minimise aggregation risk

This insight allows teams to design more stable vaccine formulations earlier in development. 

Understand complex vaccine delivery systems 

Modern vaccines increasingly rely on advanced delivery platforms such as nanoparticles, viral vectors, protein subunits and adjuvant systems. While these enhance immune response, they also introduce additional complexity in particle behaviour.

Understanding how these systems behave in solution is essential for ensuring consistent performance and manufacturability. Zetasizer provides detailed insight at the particle level.

Dynamic light scattering enables precise measurement of size distribution and interaction behaviour, helping researchers evaluate how delivery systems respond to formulation and processing conditions.

With Zetasizer, vaccine developers can:

✔ Characterise particle size and distribution with high sensitivity
✔ Monitor nanoparticle and viral vector behaviour during development
✔ Ensure consistent particle properties across formulations

This deeper understanding supports confident development of complex vaccine systems. 

Automated Workflows with the Sample Assistant 

Automated workflows powered by the Sample Assistant bring greater consistency and control to vaccine analysis. By standardising sample loading, measurement and data analysis, the system reduces operator variability and ensures that every sample is handled in the same way. This is critical when working with sensitive biological particles, where small inconsistencies can mask early signs of instability.

For vaccine systems involving nanoparticles, proteins or viral vectors, detecting subtle changes requires both sensitivity and reproducibility. The Sample Assistant delivers consistent measurement conditions across every run, enabling reliable comparison of vaccine candidates and formulation strategies.

Designed for high-throughput environments, the system allows efficient screening of multiple samples without compromising analytical performance. Dynamic light scattering and zeta potential measurements retain full sensitivity, while automation ensures reproducible datasets across larger studies.

By embedding consistency into every stage of analysis, automated workflows help vaccine development teams generate high-quality data they can trust. The result is clearer insight, improved efficiency and greater confidence in advancing vaccine candidates.

Why Zetasizer is the smart choice for vaccine development? 

Zetasizer combines analytical sensitivity, reproducibility and ease of use to address the complex challenges of vaccine development. From early research through formulation and stability testing, it provides the insight needed to understand particle behaviour in solution and reduce development risk.

With Zetasizer, you can:

✔ Detect early-stage particle aggregation with high-sensitivity dynamic light scattering (DLS)
✔ Measure zeta potential to understand surface charge and predict formulation stability
✔ Characterise nanoparticle, antigen and viral vector behaviour in solution
✔ Compare formulation conditions including pH, buffers and excipients with confidence
✔ Monitor particle behaviour at high concentrations and across processing conditions
✔ Generate highly reproducible data to support confident decision-making
✔ Enable high-throughput, standardised workflows with the Sample Assistant
✔ Screen vaccine candidates efficiently to identify stable formulations
✔ Reduce the risk of late-stage instability and reformulation
✔ Accelerate vaccine development timelines

By delivering reliable, reproducible insight into particle and molecular behaviour, Zetasizer enables scientists to make better decisions earlier, supporting the development of safe, stable and effective vaccines with confidence.

 

Explore how Zetasizer is enabling the development of biologics and pharmaceutical innovations.  

Related resources

Webinar

DLS, PCS, QELS, NIBS, MADLS, ELS - Oh my!

The basics of Dynamic Light Scattering and electrophoretic light scattering will be discussed. I will review the Dynamic Light Scattering acronyms, i.e what is meant by NIBS and MADLS.

Watch now

Watch now
Webinar

Applications of Zetasizer series across different sectors of the industry

ZetaClass is a comprehensive webinar series on dynamic and electrophoretic light scattering where our experts walk you through the basic measuring principles, data interpretation, and tests performed to gauge data quality.

Watch now

Watch now
Webinar

Live demonstration of Zetasizer Ultra

Join us as we unveil the new and expanded Zetasizer range: Zetasizer Advance.  Dr Mike Kaszuba will introduce the new range and help you to pinpoint which system best fits your particle characterization requirements.

Watch now

Watch now
Webinar

Light Scattering Methods (DLS & ELS): Separating Fact from Fiction

This webinar discusses some basic fundamentals of light scattering science and also common misconceptions about light scattering methods

Watch now

Watch now

Masterclasses: Unlocking pharmaceutical success

Masterclass webinar
Unlocking Pharmaceutical Success Masterclass 1: DLS and Zeta potential Method development with worked examples

Unlocking Pharmaceutical Success 1:

DLS and Zeta potential Method development with worked examples

In this webinar, you will learn about developing reliable and effective methods for dynamic light scattering (DLS) and electrophoretic light scattering (ELS) measurements using the Zetasizer Advance instrument. The presentation is geared toward users of DLS and ELS instruments who want to deepen their understanding of method development.

Watch now

Watch now
Masterclass webinar
Masterclass 2: Zeta potential Method Development

Unlocking Pharmaceutical Success 2:

Practical implications of USP 430

This webinar will explore how the Dynamic Light Scattering (DLS) technique, utilized by the Zetasizer Advance series, ensures compliance with United States Pharmacopeia (USP) guidelines, specifically USP 430. 

Watch now

Watch now
Masterclass webinar
Masterclass 3: Data interpretation for DLS

Unlocking Pharmaceutical Success 3:

Practical Implications of USP 432 for zeta potential measurements of pharma samples

This webinar will discuss each of the sections contained in United States Pharmacopeia (USP) 432 and what it means for users of Malvern Panalytical’s Zetasizer range of instruments who measure zeta potential in their workflow.

Watch now

Watch now
Masterclass webinar
Masterclass 4: Data interpretation for Zeta potential

Unlocking Pharmaceutical Success 4:

Zetasizer - Troubleshooting examples from customers

Join us to learn how to assess the quality of your data collected on the Zetasizer Advance instrument. Together we will go through real examples of data from particle size measurements that use Dynamic Light Scattering (DLS) and zeta potential measurements obtained with Electrophoretic Light Scattering (ELS) assessing data quality and sharing tips on how to improve confidence in the results.

Watch now