Detect antibody aggregation earlier with Zetasizer

Struggling with antibody aggregation? Discover how Zetasizer helps detect instability earlier, optimize formulations, and improve monoclonal antibody development.

Monoclonal Antibody Development

Small changes in protein behavior can compromise stability, efficacy and regulatory approval. However, many analytical techniques only detect problems after instability has already occurred. 

Malvern Panalytical's Zetasizer helps antibody developers detect instability earlier and design more robust formulations.

Using advanced dynamic light scattering and zeta potential analysis, Zetasizer provides highly sensitive insight into protein size, aggregation and molecular interactions.

With Zetasizer you can:


✔ Detect protein aggregation earlier
✔ Optimize formulation stability
✔ Understand protein interactions that drive instability
✔ Generate highly reproducible analytical data

 

Om_logo.png  Works with OmniTrust: Malvern Panalytical's compliance solution for the regulated environment

 

Would you like to speak to a specialist?
 

When you submit this form, we'll use your data to respond to your inquiry. You will also be opting in to our marketing. We’ll use your data to send you relevant updates on products services, promotions, education material and events related to your country, technology of interest and operating industry. You can unsubscribe at any time. For more information please read our Privacy Policy. 

The Hidden Risks in Antibody Development and How Zetasizer Solves Them

Even well-characterized monoclonal antibodies can fail in later stages of development due to:

  • Undetected aggregation
  • Unstable formulations
  • Protein self-association
  • High-concentration viscosity issues

These risks are a major challenge in monoclonal antibody development - especially because they often begin at the molecular level, long before they can be detected using conventional analytical techniques.

Why antibody development fails late

Subtle changes in protein behavior, such as shifts in charge, structure, or intermolecular interactions, can significantly impact stability and performance. These early-stage instabilities are frequently missed during initial screening and only become visible under stress conditions like scale-up, storage, or transport.

Zetasizer is designed to uncover these hidden risks earlier.

Using highly sensitive dynamic light scattering (DLS), Zetasizer detects even the smallest changes in particle size, allowing scientists to identify early-stage protein aggregation before it becomes a critical issue. This enables faster decision-making and reduces the likelihood of late-stage failure.

Preventing Aggregation and Self-Association

Protein aggregation and self-association are among the leading causes of biologics instability. Left undetected, they can reduce efficacy, increase immunogenicity risk, and compromise product quality.

Zetasizer provides deep insight into these behaviors by measuring both particle size and molecular interactions in solution. This allows scientists to detect self-association, oligomer formation, and aggregation at the earliest stages, long before traditional methods can identify a problem.

Optimizing formulation stability with confidence

Antibody formulations are highly sensitive to environmental conditions such as pH, buffer composition, and ionic strength. Small changes can have a significant impact on stability, solubility, and shelf life.

Zetasizer enables rapid and reliable formulation optimization.

By combining particle size analysis with robust zeta potential measurements, scientists can assess surface charge and predict how formulation conditions will influence protein stability. This allows teams to identify optimal buffer conditions, minimize aggregation, and design more robust formulations from the outset. 

Tackling High-Concentration Challenges 

As biologics move toward high-concentration, patient-friendly delivery formats, viscosity and intermolecular interactions become increasingly important.

Zetasizer helps scientists understand protein behavior at high concentrations, providing critical insight into the molecular interactions that drive viscosity challenges. This supports the development of formulations that are easier to manufacture, deliver, and administer. 

Automated Workflows with the Sample Assistant 

Automated workflows with the Sample Assistant make it easier for scientists to get the most out of Zetasizer in monoclonal antibody development. By taking care of sample loading, measurement, and analysis, the Sample Assistant reduces hands-on time and removes much of the variability that can come with manual processes. This is especially valuable when you are trying to detect subtle changes in protein behavior, such as early aggregation or self-association.

Built for high-throughput work, the Sample Assistant allows you to screen multiple antibody candidates and formulation conditions in a faster, more streamlined way. You can generate consistent, high-quality data without sacrificing the sensitivity needed for techniques like dynamic light scattering and zeta potential analysis.

When it comes to uncovering hidden stability risks, consistency is everything. Automated workflows help ensure every sample is measured in the same way, giving you greater confidence in your results across larger datasets. The result is a smoother workflow, more reliable insights, and the ability to move your antibody development forward with greater speed and clarity.

Why Zetasizer is the smart choice for monoclonal antibody development? 

Zetasizer brings together the sensitivity, reliability, and ease of use needed to tackle the most complex challenges in monoclonal antibody development. By giving scientists deeper insight into protein behavior from the earliest stages, it helps reduce uncertainty, improve formulation strategies, and avoid costly late-stage setbacks.

The result is a more streamlined development process, stronger data-driven decisions, and greater confidence in delivering stable, effective antibody therapeutics, enabling you to:

✔ Detect early-stage protein aggregation with high-sensitivity dynamic light scattering (DLS)

✔ Measure zeta potential to understand surface charge and predict formulation stability

✔ Identify protein self-association and molecular interactions in solution

✔ Optimize formulation conditions including pH, buffers, and ionic strength

✔ Analyze protein behavior at high concentrations to address viscosity challenges

✔ Generate highly reproducible, reliable data to support confident decision-making

✔ Enable high-throughput, automated workflows with the Sample Assistant

✔ Reduce late-stage development risks and costly reformulation

✔ Accelerate monoclonal antibody development timelines

✔ Support robust, stable therapeutic formulation design

 

Explore how Zetasizer is enabling the development of biologics and pharmaceutical innovations.  

Related resources

Webinar

DLS, PCS, QELS, NIBS, MADLS, ELS - Oh my!

The basics of Dynamic Light Scattering and electrophoretic light scattering will be discussed. I will review the Dynamic Light Scattering acronyms, i.e what is meant by NIBS and MADLS.

Watch now

Watch now
Webinar

Applications of Zetasizer series across different sectors of the industry

ZetaClass is a comprehensive webinar series on dynamic and electrophoretic light scattering where our experts walk you through the basic measuring principles, data interpretation, and tests performed to gauge data quality.

Watch now

Watch now
Webinar

Live demonstration of Zetasizer Ultra

Join us as we unveil the new and expanded Zetasizer range: Zetasizer Advance.  Dr Mike Kaszuba will introduce the new range and help you to pinpoint which system best fits your particle characterization requirements.

Watch now

Watch now
Webinar

Light Scattering Methods (DLS & ELS): Separating Fact from Fiction

This webinar discusses some basic fundamentals of light scattering science and also common misconceptions about light scattering methods

Watch now

Watch now

Masterclasses: Unlocking pharmaceutical success

Masterclass webinar
Unlocking Pharmaceutical Success Masterclass 1: DLS and Zeta potential Method development with worked examples

Unlocking Pharmaceutical Success 1:

DLS and Zeta potential Method development with worked examples

In this webinar, you will learn about developing reliable and effective methods for dynamic light scattering (DLS) and electrophoretic light scattering (ELS) measurements using the Zetasizer Advance instrument. The presentation is geared toward users of DLS and ELS instruments who want to deepen their understanding of method development.

Watch now

Watch now
Masterclass webinar
Masterclass 2: Zeta potential Method Development

Unlocking Pharmaceutical Success 2:

Practical implications of USP 430

This webinar will explore how the Dynamic Light Scattering (DLS) technique, utilized by the Zetasizer Advance series, ensures compliance with United States Pharmacopeia (USP) guidelines, specifically USP 430. 

Watch now

Watch now
Masterclass webinar
Masterclass 3: Data interpretation for DLS

Unlocking Pharmaceutical Success 3:

Practical Implications of USP 432 for zeta potential measurements of pharma samples

This webinar will discuss each of the sections contained in United States Pharmacopeia (USP) 432 and what it means for users of Malvern Panalytical’s Zetasizer range of instruments who measure zeta potential in their workflow.

Watch now

Watch now
Masterclass webinar
Masterclass 4: Data interpretation for Zeta potential

Unlocking Pharmaceutical Success 4:

Zetasizer - Troubleshooting examples from customers

Join us to learn how to assess the quality of your data collected on the Zetasizer Advance instrument. Together we will go through real examples of data from particle size measurements that use Dynamic Light Scattering (DLS) and zeta potential measurements obtained with Electrophoretic Light Scattering (ELS) assessing data quality and sharing tips on how to improve confidence in the results.

Watch now

Watch now